AJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Audiology Vol.8 128-136 December 1999. doi:10.1044/1059-0889(1999/015)
© American Speech-Language-Hearing Association

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sun, J. C.
Right arrow Articles by Huang, T. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sun, J. C.
Right arrow Articles by Huang, T. S.

Effect of Speech Processor Program Modifications on Cochlear Implant Recipients' Threshold and Maximum Acceptable Loudness Levels

John C. Sun 1, Margarate W. Skinner 1, S. Y. Liu 2, and T. S. Huang 2

1 Washington University School of Medicine, St. Louis, Missouri
2 Chang Gung Memorial Hospital, Taipei, Taiwan, R.O.C.

sunj{at}medicine.wustl.edu

This study's purpose was to determine whether or not modifications in speech processor electrical stimulation levels were associated with changes in five Nucleus 22 cochlear implant recipients' thresholds or maximum acceptable loudness levels (MALs). These modifications in minimum and maximum stimulation levels were made to optimize hearing in everyday life. One threshold and one MAL were obtained on each active electrode during six, weekly test sessions, three before and three after program modification. Only one participant had a significant change in threshold after program modification; this participant and four others had significant changes in MAL. Participants' threshold variability was the same, but MAL variability was higher than that observed in other studies. Because these participants had no experience making MAL judgments prior to this study, this result suggests that implant recipients should be given sufficient practice in making MAL judgments to provide a stable clinical estimate of the upper boundary of the electrical dynamic range.

Key Words: cochlear implant, threshold, maximum acceptable loudness level, speech processor program, hearing change