AJA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Audiology Vol.10 91-98 December 2001. doi:10.1044/1059-0889(2001/009)
© American Speech-Language-Hearing Association

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow My Folders
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cox, R. M.
Right arrow Articles by Gray, G. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cox, R. M.
Right arrow Articles by Gray, G. A.

Verifying Loudness Perception After Hearing Aid Fitting

Robyn M. Cox 1 and Ginger A. Gray 2

1 The Department of Veterans Affairs Medical Center, Memphis, TN, and the University of Memphis, Memphis, TN
2 The University of Memphis, Memphis, TN

During the verification phase of a hearing aid fitting, clinicians often want to assess the extent to which loudness perceptions for amplified sounds are similar to those typical of normal hearers. This type of verification calls for a criterion for "normal" loudness perception of sounds presented in a sound field. This research sought to answer several questions about the parameters of a valid "normal" criterion for a verification procedure using the Contour test of loudness perception. Loudness data were obtained from 30 listeners with normal hearing. Results indicated that a loudness growth function obtained with earphone listening is not an appropriate normative reference for hearing aid fitting verification. Instead, the normative data should be based on sound field listening. Results also indicated that the same normative function could be used to assess both unilateral and bilateral fittings. Further, it is likely that the same normative function can be used for most frequency responses that are likely to be used in feasible fittings. Finally, it was found that a previously published normative function obtained using an automated test procedure was not faithfully replicated using a carefully executed fully manual test procedure. We concluded that, until a replicable normative function is established, practitioners will need to generate their own local norms to perform postfitting verification of loudness normalization.

Key Words: loudness, hearing, hearing aid, hearing test

Submitted on January 25, 2001
Accepted on August 15, 2001




This article has been cited by other articles:


Home page
TRENDS AMPLIFHome page
S. Scollie, R. Seewald, L. Cornelisse, S. Moodie, M. Bagatto, D. Laurnagaray, S. Beaulac, and J. Pumford
The Desired Sensation Level Multistage Input/Output Algorithm
Trends in Amplification, December 1, 2005; 9(4): 159 - 197.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
All ASHA Journals AJA AJSLP JSLHR LSHSS
Copyright © 2001 by the American Speech-Language-Hearing Association.